BRAINY24

CONTROL UNIT 24 VDC WITH INTEGRATED RECEIVER

Category: BRAINY24
  • 24 Vdc
  • This function automatically adjusts the operational parameters for simplifying the system’s installation and testing operations
  • 64 transmitters storable inside the receiver
  • Control unit that manages the encoder for maximum precision during the automation manoeuvring steps
  • This is used to set the number of cycles after which the required maintenance of the system is signaled
  • Compatibility with Advantouch device. The system allows a simplified management of transmitters and receivers, with the possibility of managing lists by deleting or storing transmitters in an easy and quick manner
  • This allows a code to be entered for protection of the control unit programming, to prevent access to menus and modification of parameters

24 Vdc

This function automatically adjusts the operational parameters for simplifying the system’s installation and testing operations

64 transmitters storable inside the receiver

Control unit that manages the encoder for maximum precision during the automation manoeuvring steps

This is used to set the number of cycles after which the required maintenance of the system is signaled

Compatibility with Advantouch device. The system allows a simplified management of transmitters and receivers, with the possibility of managing lists by deleting or storing transmitters in an easy and quick manner

This allows a code to be entered for protection of the control unit programming, to prevent access to menus and modification of parameters

BRAINY24

APPLICATION
1 or 2 actuators for swing gates, opposed sliding gates, and industrial folding doors with a maximum of 2 sections
CONTROL UNIT POWER SUPPLY
230 Vac – 50/60 Hz
MOTORS POWER SUPPLY
24 Vdc
MAIN FUNCTIONS
Integrated LCD display | Integrated 433.92 MHz 64-code receiver with 3 encoding systems (Advanced Rolling Code, Rolling Code, Fixed Code) | Removable terminal boards | Separate limit switch inputs for each motor | Open, close, and pedestrian inputs | Photocell inputs in opening-closing and in closing phases | Input for N.C. or 8K2 sensitive edge | Output for electric lock 12 Vdc | Output for configuration as gate open indicator, service light, second radio channel and photocell testing | Autosetting of operating parameters | Separate electronic torque adjustment for each motor | Anti-crushing safety through amperometric detection and encoder management | Separate adjustable slowdowns for each motor in opening and closing phases | Advantouch system to configure parameters and manage radio transmitters | Number of maneuvers | Programming access password | Maintenance warning